Occupancy is a defined legal term in building construction and building codes. It refers to the use or intended use of a building or part thereof for the shelter or support of persons, animals or property. A closely-related meaning is the number of units in such a building that are rented or leased, or otherwise in-use. The lack of occupancy in this sense is a vacancy.

Contents

It is possible to have multiple occupancies (or building uses) within one building. For instance, one may have a high-rise building, where the lower levels are occupied by retail stores, whereas the upper levels could be residential.

Different occupancies within one building are separated by a fire barrier[1] with a defined fire-resistance rating. It is common for a penetration, such as a fire door, to have a fire protection rating lower than the wall fire resistance rating in which it is installed[2]. For example, a two-hour fire separation normally requires fire doors rated at 90-minutes.

For some high challenge occupancies[3] the code requirements for an occupancy separation are more stringent than for other fire-barriers, even with an identical fire-resistance rating. In this case, an occupancy separation with a two-hour fire-resistance rating may not be able to de-rate its closures, such fire doors or firestops. For example, a two-hour rated high challenge fire wall[4] requires 2 hr rated fire doors.

Firestops in occupancy separations are also more likely to be required not only an equal fire protection rating (a fire-resistance rating for closures) but must also provide a temperature rating, such that the components of the firestop systems, including the penetrants, are not permitted to rise in temperature above 140°C (284°F) on average or 180°C (356°F) on any single point, so as to lower the likelihood of auto-ignition on the unexposed side. In this manner, occupancy separations are treated similarly to fire walls, which are structurally stable in case of a fire, limiting fire-induced building collapse.

In this sense, there are two occupancies in most single-family homes: the garage and the living space of the home. Because automobile gasoline or petrol is flammable, an occupancy separation is often required between the two, should there be a vehicle fire. Water heaters and central heating are often placed in this space as well, for their use of natural gas, propane, or other fossil fuels in combustion. This also helps to prevent carbon monoxide poisoning.

Occupancy can also refer to the number of units in use, such as hotel rooms, apartment flats, or offices. When a motel is at full (100%) occupancy, a NO VACANCY neon sign is often turned on (though the sign often still says VACANCY at other times). Office buildings and apartments in particular aim for full occupancy, but if too many are built in an area this is often not the case. Completely vacant buildings can also attract crime, and are eventually targeted for redevelopment or at least renovation.

Occupancy can also mean the number of persons using an undivided space, such as a meeting room, ballroom, auditorium, or stadium. As with building codes, fire-protection authorities often set a limit on the number of people that can occupy a space, primarily because they must be able to leave the building through the available number of exits in a reasonable amount of time, without tripping or trampling each other in a panicked stampede, possibly blinded by smoke. The integrity of a structure may also be at stake, because too many people will put excessive weight and other forces, leading in some cases to a collapse.

An occupancy sensor is a device that can tell if someone is in a room, and is often used in home automation and security systems. These are typically more advanced than motion sensors, which can only detect motion.

  1. ^ NFPA 5000® Building Construction and Safety Code® 2006 Edition, Chapter 6 Classification of Occupancy, Classification of Hazard of Contents, and Special Operations, section 6.2.4
  2. ^ NFPA 5000® Building Construction and Safety Code® 2006 Edition, Chapter 8 Fire-Resistive Materials and Construction, Table 8.7.2 Minimum Fire Protection Ratings for Opening Protectives in Fire Resistance–Rated Assemblies
  3. ^ NFPA 5000® Building Construction and Safety Code® 2006 Edition / Chapter 8 Fire-Resistive Materials and Construction, Table 8.7.2 Minimum Fire Protection Ratings for Opening Protectives in Fire Resistance–Rated Assemblies
  4. ^ NFPA 5000® Building Construction and Safety Code® 2006 Edition, section 8.3

In transport engineering, occupancy can refer to:

  1. The number of passengers occupying a vehicle.
  2. The percentage of time in which a detector is occupied by a vehicle.

Advanced Search
Included Web Search Engines


Safe Search

close

Top Matching Results

Occasionally Search.com will highlight specialized results that are based on the context of your query. Examples of specialized results include specific links to news, images, or video.

Top Matching Results may highlight information from other Search.com pages, content from the CNET Network of sites, or third party content. The listings are based purely on relevance. Search.com does not receive payment for listings in this section but our partners that provide this data may get paid for listing these products.

Sponsored Links

This section contains paid listings which have been purchased by companies that want to have their sites appear for specific search terms and related content. These listings are administered, sorted and maintained by a third party and are not endorsed by Search.com.

Search Results

Search.com sends your search query to several search engines at one time and integrates the results into one list which has been sorted by relevance using Search.com's proprietary algorithm. You can customize the list of search engines included in your metasearch from the preferences.

The search engines that are used in your metasearch may allow companies to pay to have their Web sites included within the results. To view the Paid Inclusion policy for a specific search engine, please visit their Web site. Search.com does not accept payment or share revenue with any search engine partner for listings in this section.